Alarm Lock ALC-8 Spécifications

Naviguer en ligne ou télécharger Spécifications pour Claviers numériques Alarm Lock ALC-8. Alarm Lock ALC-8 Specifications [en] Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 16
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Securitron Magnalock Corp. Tel 800.624.5625 ASSA ABLOY, the global leader
Phoenix, AZ www.securitron.com
in door opening solutions
© Copyright, 2011, all rights reserved PN# 500-10420
Page 1 Rev. F, 02/11
MAGNALOCK MODELS M32, M62 AND M82B
INSTALLATION INSTRUCTIONS
1. INTRODUCTION
The Securitron Magnalock family represents the state of the art in electromagnetic locking.
There are three (3) models with operational electrical characteristics including mounting
configuration options addressed in this manual.
The BondSTAT “B” Magnalock Series, Bond Sensor, monitors the magnetic field. An internal
sensor activates a SPDT dry contact relay connection designed for interface to access control
and/or alarm systems for reporting the status of the Magnalock. (Section 5.2.4)
The DPS “D” Magnalock Series, Door Position Sensor, is activated by a special magnetic strike
armature assembly. The isolated SPDT reed switch, with an internal resettable protection device,
is designed for interface to access control and/or alarm system for door status. (Section 5.2.4)
2. SPECIFICATIONS
MODEL M32 M62 M82B
Holding Force 600 Lbs [272 kg] 1200 Lbs [544 kg] 1800 Lbs [816 kg]
Dimensions: Length
8" [203mm]
8" [203mm]
12" [305mm]
Height
1.88" [48mm]
3" [76mm]
3" [76mm]
Depth
1.6" [41mm]
1.75" [44mm]
1.75" [44mm]
Dual Voltage
12/24 Volts DC
Current: @ 12 VDC
300mA 250mA 350mA
@ 24 VDC
150mA 150mA 200mA
Capacitance: @ 12 VDC
6.8 mF 44 mF 44 mF
@ 24 VDC
6.8 mF 11 mF 11 mF
BondSTAT Rating Voltage: 30 VDC (Maximum) ~ Current: 1 Amp (Maximum)
DPS Rating Voltage: 30 VDC (Maximum) ~ Current: 125 mA (Maximum)
3. PRODUCT OVERVIEW
Upon unpacking this product, an inventory should be made to ensure that all the required
components and hardware have been included. Along with these instructions and the
installation template, the lock assembly should include the following items:
Figure 1
Magnalock
Sex Bolt
Strike Plate
Hardware Pack
Vue de la page 0
1 2 3 4 5 6 ... 15 16

Résumé du contenu

Page 1 - INSTALLATION INSTRUCTIONS

Securitron Magnalock Corp. Tel 800.624.5625 ASSA ABLOY, the global leader Phoenix, AZ www.securitron.com in door opening solutions techsupport@

Page 2

PN# 500-10420 Page 10 Rev. F, 02/11  SFP – Stop Filler Plate – The SFP bracket is designed for extending the door frame mounting surface 1-

Page 3 - Page 3 Rev. F, 02/11

PN# 500-10420 Page 11 Rev. F, 02/11 APPENDIX A Troubleshooting Problem Lock Does Not Generate a Magnetic Field Points of Reference Check f

Page 4 - Page 4 Rev. F, 02/11

PN# 500-10420 Page 12 Rev. F, 02/11 Appendix B Wire Gauge Factoring 1.1 Remote Power Supply  The Magnalock requires adequate voltage and

Page 5 - Page 5 Rev. F, 02/11

PN# 500-10420 Page 13 Rev. F, 02/11 TO SOLVE: INTERSECT ROW (Current) and INTERSECTING COLUMN (Wire Distance) 1.00A 20 Gauge 18 Gauge 16 G

Page 6

PN# 500-10420 Page 14 Rev. F, 02/11 MAGNACARE LIFETIME REPLACEMENT WARRANTY For warranty information visit www.securitron.com/en/site/securi

Page 7 - Page 7 Rev. F, 02/11

PN# 500-10420 Page 15 Rev. F, 02/11

Page 8

PN# 500-10420 Page 16 Rev. F, 02/11 Why choose a genuine Magnalock ? The Securitron Advantages... Electrical Advantages • Low Current Consu

Page 9 - Page 9 Rev. F, 02/11

PN# 500-10420 Page 2 Rev. F, 02/11 4. RECOMMENDED TOOLS Power Drill Hammer Wire Strippers/Cutter 1/8”, 3/8”, 1/2” Drill Bits Center Punc

Page 10 - Page 10 Rev. F, 02/11

PN# 500-10420 Page 3 Rev. F, 02/11 Mounting the Strike Plate The strike plate should be mounted prior to the magnet in out-swinging door appl

Page 11 - (800) 624-5625

PN# 500-10420 Page 4 Rev. F, 02/11 Figure 4 below illustrates a typical Magnalock out-swinging door installation. Figure 4 Blind nuts MU

Page 12 - Page 12 Rev. F, 02/11

PN# 500-10420 Page 5 Rev. F, 02/11 Lock/Strike Installation for “B” and “D” Magnalocks IMPORTANT! PLEASE READ AND APPLY THIS INFORMATION WHE

Page 13 - IMPORTANT

PN# 500-10420 Page 6 Rev. F, 02/11 Single Lock - Double Door Magnalock Mounting A single Magnalock can be used to secure double doors using a

Page 14 - Page 14 Rev. F, 02/11

PN# 500-10420 Page 7 Rev. F, 02/11 GATE STYLE OPERATIONS AND INSTALLATION TECHNIQUES Figure 9 5.3 ELECTRICAL INSTALLATION 5.3.1 General C

Page 15 - Page 15 Rev. F, 02/11

PN# 500-10420 Page 8 Rev. F, 02/11 Electrical Wiring The following diagrams, Figures 12, 13, 14 and 15 represent the proper electrical wirin

Page 16 - The Securitron Advantages

PN# 500-10420 Page 9 Rev. F, 02/11 BondSTAT Sensor status wiring description  The green and white wires supply electrical connection when t

Commentaires sur ces manuels

Pas de commentaire