PROGRAMMING EXAMPLE – FIGURE 1 (Numerical Data)
Zone 1 LED = 1
Zone 4 LED = 8
}
Data = 9
Zone 2 LED = 2
Zone 7 LED = 64
}
Data = 66
To change data in a
segment, enter the data
followed by []
Enters the previous
programming “location”.
Pressing [#] will exit a
location without
changing the data in
the current segment.
programming “location”.
Returns to the “location” just
programmed.
PROGRAMMING EXAMPLE –
FIGURE 2
(Feature Selection Data)
Location 23 Segment 1
1 = Quick Arm
2 = Re-Exit
3 = Auto Bypass
4 = Silent Keypad Panic
5 = Audible Keypad Panic
6 = Keypad Auxiliary 1
7 = Keypad Auxiliary 2
8 = Multi-Keypad Tamper
Press the key on the numeric keypad that corresponds to the feature you wish to enable/disable. When an LED is
“on, a feature is enabled; when “off” the feature is disabled. For example: With the 1, 5, & 7 LEDs “on”, Quick Arm,
Audible Keypad Panic and Keypad Auxiliary 2 are enabled.