Alarm Lock Trilogy PDK3000 Series Manuel d'instructions

Naviguer en ligne ou télécharger Manuel d'instructions pour Systèmes de contrôle d'accès de sécurité Alarm Lock Trilogy PDK3000 Series. Alarm Lock Trilogy PDK3000 Series Programming instructions Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 40
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
1
WI1120E 5/07
Trilogy
PDK3000 Series
Programming Instructions
PDK Trilogy Series
Standalone Access Control Systems
with ProxCard Access
PDK3000
345 Bayview Avenue
Amityville, New York 11701
For Sales and Repairs 1-800-ALA-LOCK
For Technical Service 1-800-645-9440
Publicly traded on NASDAQ Symbol: NSSC
© ALARM LOCK 2007
HID
HID CORPORATION
PROXCARD
®
PROXKEY
®
KEYFOB
DL-WINDOWS PROGRAMMING
SOFTWARE
AL-DTM
DATA TRANSFER
MODULE
AL-PRE PROXCARD
®
READER / ENROLLER
AL-IR1 PRINTER
Vue de la page 0
1 2 3 4 5 6 ... 39 40

Résumé du contenu

Page 1 - Trilogy

1 WI1120E 5/07 Trilogy PDK3000 Series Programming Instructions PDK Trilogy Series Standalone Access Control Systems with ProxCard Access PDK3000

Page 2 - PDK3000 SERIES LOCK

10 NOTE: The AL-PCI cable is designed to be used on a 9 pin serial COM port. If your computer has a 25 pin COM port, a 25 pin to 9 pin adapter must

Page 3 - PDK Series Lock Features

11 WIRING See the Installation Manual for detailed illustrations and additional information. External Power: Red / Black wires - External 12-24 Volts

Page 4 - Supported Products

12 BASIC WIRING: PDK3000 Interfacing to an access control system to allow code access in addition to keyfob access. Auxiliary Relay is not connected

Page 5 - Lock Design Overview

13 TYPICAL APPLICATION: PDK3000 Using a normally open push-button switch to provide passage via the door strike, and the Auxiliary Output to trigger

Page 6

14 Quick Start First Time Start Up 1. Unpack the lock. 2. With the power disconnected, hold down the ; key for 10 seconds and release. 3. Connec

Page 7 - What is DL-Windows?

15 Quick Start (cont’d) Delete a User Code 1. Enter Program Mode (if not in already). 2. Press ; 2 ; [User Number] :. The lock will flash

Page 8 - Programming Levels

16 Verifying Basic Keypad User Codes Test a valid User Code: VALID CODE - The Green LED will flash momentarily and the sounder will beep a few times

Page 9 - LED and Sounder Indicators

17 Function 1 Change Master Code See page 18 Function 2 Add/Delete/Change User Codes See page 18 Function 3 User Disable (By User Number) See page

Page 10 - PDK3000

18 1. New Master Code (User Number 1) 2. Add/Delete/Change User Codes 2-2000 ; 1 ; [ _ _ _ _ _ _ ] ; [ _ _ _ _ _ _ ] : (New Master

Page 11 - SPECIFICATIONS

19 USERS (Continued) ; 6 : 6. Enable Total User Lockout Mode (This Function enabled through keypad only) 7. Disable Total User Lockout Mode (This Fun

Page 12

2 Table of Contents PDK Series Lock Features ... 3 Supported Products ... 4 Lo

Page 13

20 CLEAR FUNCTIONS Group Enable/Disable Enter the functions below to Enable/Disable Groups. Functions 14 - 23 will each override existing scheduled e

Page 14 - Quick Start

21 GROUPS Group Enable/Disable with Timeout (Enter Timeout, XXX Hours) (Functions 25-34 are enabled through the keypad only) • Hours must be between 1

Page 15 - Quick Start (cont’d)

22 ; 3 8 ; [ _ _ _ _ _ _ ] : (Date) 38. Set Date • Use Month Day Year format - MMDDYY - Single digit months and days are entered with a preced

Page 16 - Testing the Codes Entered

23 ; 4 3 ; [ _ _ ] : (seconds) 43. Speed Up Clock (This Function enabled through keypad only) ; 4 4 ; [ _ _ ] : (seconds) 44.

Page 17

24 49. Disable Permanent Passage Mode (This Function enabled through keypad only) 50. Return Lock to Normal Passage Mode Schedule (This Function enabl

Page 18 - Programming Functions

25 ; 5 5 : ; 5 7 : 57. Print Clock Settings, Software Version and Door Number 55. Print Audit Trail ; 5 6 : 56. Print User Code List ; 5 8 : 58.

Page 19 - User Lockout Mode

26 60. Number of Attempts Before Lockout 61. Set the Attempts Lockout Time • Number of attempts before lockout must be 1-9 attempts. • The number of

Page 20 - PRIORITY ORDER

27 ; 6 7 ; [ _ _ ] : (Event Number) 67. Add System Features SYSTEM FEATURES 68. Delete All Relay Features added by Function 67. ; 6 8 ;

Page 21

28 Scheduled Passage and Group Use the functions below to enable Passage Mode and enable/disable Groups at the time programmed. • For day enter: 1 for

Page 22 - 40. Set Weekday

29 QUICK SCHEDULES 84. Business Quick Schedule 7AM-5PM, Monday - Friday (This Function enabled through keypad only) ; 8 4 ; [ _ ] : (Group) ; 8

Page 23 - Clock Adjust

3 Audit Trail • 40,000 Event Capacity • Entries Logged with Time and Date • Critical Programming Events Logged • Printable using the AL-IR1 Hand-Held

Page 24 - Pass Time

30 To Disarm a Burglary Control Panel 90. Relay Activation (Open Time Window) ; 9 0 ; [ _ ] ; [ _ _ _ _ ] :

Page 25 - 58. Upload/Download PC Data

31 ; 9 9 ; 0 0 0 : 99. Clear All Lock Programming (This Function enabled through keypad only) Clears all programming, and returns lock to factor

Page 26 - Remote Input

32 Groups and Scheduled Group 1 Examples The following examples detail the more advanced features of the PDK series locks. Although all features and

Page 27 - 67. Add System Features

33 Groups and Scheduled Group 1 Examples (cont'd.) Functions 90/91: Use Function 90 and 91 (see page 30) to create a window of time where if any

Page 28 - Enter Key

34 Function Number(s) Function Name Programming 43/44 Clock Adjust 52/53/54 Pass Time (3 sec)  10 sec  15 sec  60 Set Loc

Page 29

35 User Number (1-2000) User Code (3-6 digits) User Name 1 2 3 4

Page 30 - (Close Time Window)

36 Day(s) Function Number Up to 500 scheduled functions can be programmed (Up to only 150 using AL-DTM2). For Day Enter : 1 = Sunday, 2 = M

Page 31 - [ _ _ _ _ ] :

37 ACCESS = Entry into a restricted area. AMBUSH = A special Code entered at the keypad when the User is forced to unlock a device. The device unlock

Page 32 - Assign a User to Two Groups

38 entries (1-9), that will disable the keypad for a predefined period of time (1-60 seconds). LOCKOUT TIME = A predefined time (1-60) seconds that t

Page 34 - (9) (9)

4 Data Transfer Module (AL-DTM) An AL-DTM can be used to transfer Lock Programs (and other data) between DL-Windows and locks. When computers cannot

Page 35

40 ALARM LOCK LIMITED WARRANTY ALARM LOCK SYSTEMS, INC. (ALARM LOCK) warrants its products to be free from manufacturing defects in materials and wor

Page 36

5 Lock Design Overview Why Use Software inside a Lock? With ordinary door locks, the need to make physical copies of metal keys and distributing them

Page 37 - Glossary

6 Terminology Used in this Manual What is a Lock Program? A Lock Program contains the instructions that a lock uses to per-form its various functions.

Page 38 - Glossary (cont'd)

7 word "Slot" is also used. They all mean the same thing. Since User Numbers are fixed, knowing a User Number will spec-ify the associated

Page 39

8 USER TYPE USER NUMBER GROUP DEFAULT ASSOCIATION MINIMUM PROGRAM LEVEL (See page 6) Master Code 1 - M Installer Codes 2 & 3 none 4 Manag

Page 40 - ALARM LOCK LIMITED WARRANTY

9 ACTIVITY LED SOUNDER COMMENTS Keypress 1 RED Flash 1 Beep Normal Operation Access Granted or Remote Release 3 GREEN Flashes 3 Beeps Remote