Lock Operation
Important: Before attempting to program any codes or
functions, Note the following:
While the lever or knob may be rotated at any time, the latch
will not be engaged to unlock the door unless a valid code has
been entered.
When a valid code is entered, the lock will unlock immediately
and remain unlocked for about 3 seconds (or longer, if
reprogrammed by functions 53 and 54).
Programming - Notes
It is recommended that all programming be prepared in advance
using the DL3500 Programming Sheets for reference while
programming (see User Code and Schedule Recording sheets
at the back of this manual), then be secured when finished.
PROGRAM LEVELS
You must have the programming authority level equal to the
authority level required to access a programming function.
Programming authority levels can have a value of 1, 2, 3, 4 or M.
A programming authority level of M (Master) is associated with
the Master Code and cannot be associated with any other user.
CODE TYPES
Program level ability is fixed according to table on page 11. The
codes are defaulted to the tabulated group associations when
adding codes using Program Function 2.
Master Code - User 1: Always enabled and can program all
functions, can't be group associated.
Installer Codes - Users 2 & 3: Allow all functions except
master code change.
Manager Codes - Users 4 - 6: Can program all functions
except functions relating to lock configuration, no default group
association.
Supervisors - User 7 - 9: Can only program functions relating
to day to day operation, no default group association.
Print Only Codes - Users 10 & 11: Allow access to print audit
trail only.
Basic User Codes: No program ability, default group
association.
Program Level Required - The
program level required to access
the Function. Possible
Programming Levels of 1,2,3,4 and
M, where M = Master Code.
Program Authority Level of User
must be equal to the Function that
is to be accessed.
3. Disable User
; 3 ; [ _ _ _ ] :
4. Enable User
; 4 ; [ _ _ _ ] :
User Number must be between 2 and 300.
NOTE: Will Enable/Disable users even if the user is associated with a enabled group.
2
Enabling/Disabling Users (By User Number)
Programming key sequence.
Function Name
Programming
Information
If a wrong key is pressed during code entry, hold any key continuously until the error sound is heard (7 short beeps),
this will clear the entry, then re-enter the key sequence again.
General Program Mode Information
Visible LED and Audible Sounder Indicators
Normal Battery
Activity LED SOUNDER
Keypress 1 RED Flash 1 Beep
Enter Valid Enabled Code 3 GRN Flashes 3 Beeps
Enter Invalid No/Wrong Code 6 RED Flashes 6 Beeps
Successful Program Entry 2 GRN Flashes 2 Beeps
Unsuccessful Program Entry 7 RED Flashes 7 Beeps
Low Battery is indicated by a Yellow Flash during Key Press and a Long Beep.