Alarm Lock Trilogy DL2800 Manuel d'instructions Page 11

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 36
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 10
11
ACTIVITY LED SOUNDER COMMENTS
Keypress 1 RED Flash 1 Beep Normal Operation
Access Granted or Remote Input 2 GREEN Flashes 2 Beeps For Remote Input, wire a normally
open contact to these two white
wires. Momentarily close to
unlock. See page 10 for more in-
formation.
Valid Code 1 Momentary GREEN
Flash
Invalid Code 6 RED Flashes 6 Beeps Re-enter User Code
Successful Program Entry 1+2 GREEN Flashes 1+2 Beeps When in Program Mode
Unsuccessful Program Entry 7 RED Flashes 7 Beeps When in Program Mode
Enter Program Mode 2 YELLOW & 1 GREEN
LED Flash
Exit Program Mode 1 RED, 2 GREEN,
1 RED Flashes
2 Groups of 5
Beeps
Valid but Disabled Code 1 RED, 1 GREEN, 4
RED Flashes
1 long, 5 short
Beeps
Code exists in memory, but dis-
abled
Low Battery upon User Code En-
try or upon closing of Remote Re-
lease switch
YELLOW Flash during
key presses
Steady 4-Second
Tone
LED and sounder indications occur
only when a valid code is entered.
See page 10 before changing bat-
teries
User Code Entered YELLOW Flash Sequence of 7
Beeps Repeated 4
Times
Non-fatal memory or clock error
has been detected. Under this
condition, unexpected operation is
possible. Remove power and re-
start. Do not mistake the low bat-
tery indication as a memory or
clock error
Button Press Continuous Series
of Beeps
System Fault. Ensure batteries
are fresh
LED and Sounder Indicators
The DL Series locks provide visual and audible keypad feedback. With a fully charged battery, the LED and sounder feedback
is as follows: