The Programming Level defines which Programming Func-
tions a User is allowed to perform. Each User Number is as-
sociated with a defined level of ability--a Programming Level-
-as to which Functions the assigned User can access. The
highest level--Master--allows access to ALL Functions.
In addition, each Function (see pages 14-26) has its own fixed
Programming Level.
A User must possess a Programming Level equal to the
Programming Level of the Function in order to access that
Function.
Programming Levels can have a value of "1", "2", "3", "4" or
"M". Note: Having a Programming Level of "3" does not allow
access to Functions with Programming Levels of 1, 2 or 4.
The following defaults apply when adding User Codes via Pro-
gramming Function 2:
Master: The highest level User, and always associated with
User Number 1 and its Master Code only. Master is al-
ways enabled and can program ALL Functions.
(Abbreviated as the Programming Level = "M").
Manager: Always associated with User Numbers 2-6. Can
program all Functions except Functions relating to lock
configuration. (Abbreviated as Programming Level = "1",
"2" or "3").
Supervisor: Always associated with User Numbers 7-11.
Can only program Functions relating to certain day to day
operations. (Abbreviated as Programming Level = "1" or
"2").
Basic Users: Always associated with User Numbers 12
through 200. When adding User Codes for Basic Users via
Programming Function 2, Programming Levels are not as-
signed by default. Note: Programming Levels for Users 2-
200 can be assigned via Function 8.
Programming Levels
Users programmed with Function 2 will default to a Group
Association and a Programming Level Ability as follows:
USER TYPE USER NUMBER DEFAULT
GROUP ASSOCIATION
DEFAULT
PROGRAMMING LEVEL
Master Code 1 none M, 4, 3, 2, 1
Manager Codes 2 - 6 none 3, 2, 1
Supervisor 7 - 11 none 2, 1
Basic User Codes 12 - 50 none none
Basic User Codes Group 1 51 - 100 1 none
Basic User Codes Group 2 101 - 150 2 none
Basic User Codes Group 3 151 - 200 3 none
Initiate DTM (Non-Pass Code) 299 none none
Service Code 300 none none
User 299 is a Non-Pass Code. This is the only code that will initiate data transfer with the AL-DTM.