16
CLOCK ADJUST
; 4 3 ; [ _ _ ] :
(seconds)
43. Speed Up Clock
; 4 4 ; [ _ _ ] :
(seconds)
44. Slow Down Clock
Number of seconds to Speed Up/Slow Down clock each day must be 0-55 seconds.
Always consider the current setting when using this function. (Use of this function is not
cumulative.) For example, if the clock needs to be sped up 10 seconds per day and the
current setting is 10, program 20 seconds using Function 43.
Example 1: Clock is losing 13 seconds every day, enter:
; 4 3 ; 1 3 :.
This example assumes that the clock adjust setting was at the factory default of zero.
Function 57 can be used to print the current clock adjust setting.
Example 2: Clock is gaining 13 seconds every day, enter:
; 4 4 ; 1 3 :.
This example assumes that the clock adjust setting was at the factory default of zero.
Function 57 can be used to print the current clock adjust setting.
Example 3: To set the clock adjust setting back to the factory default of zero, enter:
; 4 3 : or ; 4 4 :
Clock Adjust
4
; 4 5 :
45. Enable Passage Mode
; 4 6 :
46. Disable Passage Mode
47. Timed Passage Mode
; 4 7 ; [ _ _ _ ] :
(XXX Hours)
Allows passage through the door without the need for a code using Function 45. Re-Lock
using Function 46.
Programmed Schedules will override the state of the lock using functions 45 and 46. If it
is required that programmed schedules do not override passage mode, Enable/Disable
Passage Mode Enable/Disable - Schedule will Override
2
Hours must be between 1 - 999.
Allows passage through the door without the need for a code for the programmed amount of
time.
2
PASSAGE MODE