STANDARD FEATURES FOR 700 & 710 SERIES
UNIT IS NON-HANDED
DEADBOLT WITH HARDENED STEEL INSERT
DEADLATCH FOR EASY ACCESS FROM INSIDE WITHOUT ALARM
DEADBOLT CAN BE OPERATED BY OUTSIDE KEY
LOCK ONLY REQUIRES 5 TO 10 LBS. OF FORCE TO OPERATE
CAN BE USED FOR SINGLE OR DOUBLE DOORS
LOUD DUAL PEZO HORN
SELECTABLE - CONTINUOUS OR TWO MIN. ALARM SHUTDOWN
DISARMING BEEP WHEN BOLT IS RETRACTED WITH KEY
LOW BATTERY BEEP WHEN BATTERY NEEDS TO BE REPLACED
RETRIGGERABLE ALARM AFTER TWO MIN. SHUTDOWN FOR MODEL
710 ONLY
INSTALLATION
SINGLE DOOR PAIRS OF DOORS
PAIRS OF DOORS
WITH CENTER MULLIONS
Only one Exit Lock is required for
each emergency exit door of this type
If two exit devices are not required, use one
lock with a Model 732 Double Door Keeper -
plus one Model 44 Double Door Holder on
the inactive door (or a vertical rod)
Pairs of this style should be treated as
two single exit doors. Use two Locks for
maximum safety and security.
ELECTRONIC PANIC LOCK ACCESSORIES:
FINISH BACK PLATE MODEL 767
Required to conceal the open back of the
lock body when mounted on a glass door.
Stainless Steel 4.5" x 8.5".
DOUBLE DOOR KEEPER MODEL 732
Applied to the surface of the inactive leaf of a
pair of doors. Plated Case Aluminum 7/8" x 6"
ARMORED DOOR LOOP MODEL 271
For use with Electrified locks.
An easy means for bringing electric current
from the hinge side of a door frame to the door.
18" flexible armored cable. End brackets are
deep drawn anodized aluminum to conceal
wire connections.
DOUBLE DOOR HOLDER MODEL 44
The Double Door Holder secures the inactive
door to the door frame while the active door is
closed. Releasing the active door automatically
allows both doors to swing freely. Reversible,
right or left hand doors. Cast aluminum 8.5"
long, 3" wide and 2.5" high.
THUMB TURN
MODEL THT
Used instead of cylinder
and keys to retract and
project the deadbolt
from inside.
CYLINDER
FINGER PULL
MODEL 711
An inexpensive door pull for use
when outside key only access is
required.
RIM CYLINDER
MODEL CER-OKC
Used to lock and unlock all
our exit and panic alarm locks
from outside. Includes two
keys for outside key control
(KA or KD).
OUTSIDE ACCESS
DOOR PULL MODEL 707
For access from build-
ing exteriors. Installed
on the outside of the
door and linked to the
lock. After deadbolt is
retracted by outside
key, a slight pull will
release the deadlatch
and open door. Cast
aluminum, 8" x 1.5".
SINGLE DOOR KEEPER
MODEL 730
Supplied for single doors or pairs of
doors with mullions.
LATCH HOLDBACK
DEVICE MODEL 747
An integral lock modifica-
tion which "dogs" the
latchbolt to provide a
hold-open function. Sim-
ply depress the latchbolt
beyond the face of the
lock and it will remain
retracted until the door is
relocked by key..
BATTERY ELIMINATOR MODEL AC-9
The AC-9 battery eliminator provides constant
regulated 9VDC power for Models 250 and
260. It is simple to install and maintenance
free. 117 VAC to 9VDC. The AC-9 conserves
the battery which automatically takes over as
the power source in the event of a power failure
or intentional power cutoff.
P5223A
Vue de la page 3
1 2 3 4 5 6

Commentaires sur ces manuels

Pas de commentaire