ES2400 – ES2403 – ES4800 - ES6000
User's Manual
___________________________________________________________________________________________________________________________________________________
When the charge is complete, the charger switches off automatically, and the MRG front panel
will give the message “COMPLETE”:
OVERVOLTAGE PROTECTION
If, during the charge, the voltage of the battery will increase above 2,80 V/cell, the charger will
shut down automatically, and the MRG front panel will show the message “Voltage High”:
SAFETY TIMER – EMERGENCY STOP
The MRG controller includes a safety timer that shuts the charger down if the battery doesn't
reach the gassing voltage within a defined time limit. This time limit is not fixed, but it depends
on the finishing time selected by the user.
If this condition occurs, the MRG front panel shows the message “Time Error”:
The cause if this problem may be a wrong setting of the input voltage: if the input is set to a
certain value (for example: 610 V) but the real voltage is lower (for example: 575 V), the
charging current will be significantly lower than the nominal value, therefore the battery will
take too long to reach the gassing voltage.