2. DESCRIPTION OF THE CHARGER
EagleSmart battery chargers have been designed to charge Lead-Acid batteries.
These units convert the AC input to a DC output at the correct voltage. The charge curve is
Wa, with programmable finishing charge time and automatic equalization.
The operation of the EagleSmart chargers is managed by the new MRG Charge Controller,
which is a microprocessor based electronic board of the last generation.
The MRG Charge Controller monitors the entire charging curve, and it incorporates several
safety features.
The front panel of the MRG charge controller is composed by 4 status LEDs (CHARGING
80% CHARGED – COMPLETE – FAULT! / ALARM !) and 3 ammeter LEDs.
3. INSTALLATION OF THE CHARGER
Conditions of use:
Operating temperature: 5°C to 45°C
Storage temperature: -20°C to 60°C
Relative humidity: less than 75%
__________________________________________________________________________________________________________________________________________________
Page 5/14
CAUTION!
Risk of electrical shock!
The charger can be installed by qualified personnel only.
To prevent fire or shock hazard, do not expose the unit to rain or moisture.
Don't use the unit in presence of flammable gas, because it can generate sparks.